Solar System Inputs

kW
×
Recommended PV multiplier for the motor load.
Wp
hrs
hrs
%
×

Calculated Outputs

24.00 kWp Recommended Solar PV
44 Solar Panels
106.48 kWh Daily Solar Generation
Motor Power (kW)
16.00 kW
Motor Power (HP)
21.45 HP
Recommended Solar PV (kWp)
24.00 kWp
Minimum VFD / Inverter
19.20 kW
Suggested VFD Standard Size
22.00 kW
No. of Solar Panels
44
Actual Installed PV
24.20 kWp
Estimated Daily Solar Generation
106.48 kWh
Motor Daily Energy Requirement
128.00 kWh
Estimated Solar Running Hours / Day
6.66 hrs
Based on the current inputs, estimated solar generation covers 83.19% of the calculated daily motor energy requirement.

How the calculation works

Recommended Solar PV

Motor Power (kW) × Solar Sizing Factor. Example: 16 × 1.50 = 24.00 kWp.

Number of Panels

Recommended PV is divided by panel wattage converted to kW, then rounded up to the next whole panel.

Daily Solar Generation

Actual Installed PV × Peak Sun Hours × System Efficiency.

Motor Energy Requirement

Motor Power (kW) × Daily Running Hours.

Minimum VFD / Inverter

Motor Power (kW) × VFD / Inverter Margin.

Solar Running Hours

Estimated Daily Solar Generation ÷ Motor Power (kW).

Need a detailed solar quotation?

Share your calculated requirement with the Decon Solar team.

Get Solar Quote
Chat with us